EPSRC National Crystallography Service
Data Collection Summary kccd2 (damien)
Summary report for Directory: home/diska/04src0088
Report generated Feb 03, 2004; 15:05:22
Unit cell
35728 reflections with 2.91°<theta<27.48° (resolution
between 7.00A and 0.77A) were used for unit cell refinement
Symmetry used
in scalepack |
p222 |
| a (Angstrom) |
9.20170 +/- 0.00010 |
| b (Angstrom) |
16.0730 +/- 0.0003 |
| c (Angstrom) |
18.2779 +/- 0.0003 |
| alpha (°) |
90.000 |
| beta (°) |
90.000 |
| gamma (°) |
90.000 |
| Volume (A**3) |
2703.28 +/- 0.07 |
| Mosaicity (°) |
0.5490 +/- 0.0010 |
Data collection
Summary
| Total number of images collected |
339 |
| Total exposure time |
40.5 minutes |
| Data collection exposure time |
39.8 minutes |
| Data collection wall-clock time |
66.8 minutes |
Experimental Conditions
| Wavelength |
0.71073 A |
| Cryostat setting |
120.00K |
| Crystal to detector distance |
35.00 mm |
Scans
| Type |
Name |
# images |
Total
Rotation |
Per frame
Rotation |
Exposure
per frame |
Used in
scaling |
| data collection |
s01f |
189 |
189.0° phi |
1.000° |
7 seconds |
Yes |
| data collection |
s02f |
33 |
33.0° omega |
1.000° |
7 seconds |
Yes |
| data collection |
s03f |
109 |
109.0° omega |
1.000° |
7 seconds |
Yes |
| Phi/Chi |
i01f - i08f |
8 |
|
|
5 seconds |
Scalepack Scaling
Deleted observations
| Rejected |
42 |
| Zero sigma or profile test |
11 |
| Overload or incomplete profile |
1400 |
| Sigma cutoff |
14 |
| High resolution limit |
66 |
Final Data Set
| Scale factor |
10.00 |
| Number of 'full' reflections |
8204 |
| Number of 'partial' reflections |
19339 |
| Total number of integrated reflections |
26080 |
| Total number of unique reflections |
3488 |
| Data completeness |
99.9% |
| Resolution range |
7.00-0.77 A |
| Theta range |
2.91°-27.48° |
| Average Intensity |
190.2 |
| Average Sigma(I) |
3.9 |
| Overall R-merge (linear) |
0.120 |
Crystal Information
| Collection Temperature |
120 K |
| Crystal Size |
0.45 x 0.3 x 0.2 |
| Crystal Colour |
colourless |
| Crystal Shape |
block |
SORTAV Absorption correction
| Max Transmission Factor |
1.10500
|
| Min Transmission Factor |
0.77274
|
N.B. The scaling summary is redundant as outliers are
treated during the absorption correction using SORTAV.
The quoted data completeness is for the stated resolution ranges, and
the Overall R-merge is that before the absorption correction. The
SORTAV transmission factors are based on a crude approximation and the
expected formula (not always correct!).
For more information visit the service web site at: http://www.soton.ac.uk/~xservice/