EPSRC National Crystallography Service

Data Collection Summary

Summary report for Directory: diska/01src007

Report generated Jan 17, 2001; 14:26:56

Unit cell

3263 reflections with 1.02°<theta<27.48° (resolution between 20.00A and 0.77A) were used for unit cell refinement

Symmetry used
in scalepack
p1
a (Angstrom)10.1254 +/- 0.0016
b (Angstrom)10.579 +/- 0.002
c (Angstrom)17.772 +/- 0.004
alpha (°)89.927 +/- 0.005
beta (°)89.958 +/- 0.006
gamma (°)93.545 +/- 0.006
Volume (A**3)1899.9 +/- 0.6
Mosaicity (°)0.703 +/- 0.012

Data collection

Summary

Total number of images collected129
Total exposure time43.5 minutes
Data collection exposure time38.4 minutes
Data collection wall-clock time53.2 minutes

Experimental Conditions

Wavelength0.71073 A

Scans

TypeName# imagesTotal
Rotation
Per frame
Rotation
Exposure
per frame
Generator settingDetector
distance
Used in
scaling
cell determinationi01f15 15.0° phi1.000°20 seconds50.00kV 65.00mA30.00 mmNo
data collections01f90180.0° phi2.000°20 seconds50.00kV 80.00mA45.00 mmYes
data collections02f24 48.0° omega2.000°20 seconds50.00kV 80.00mA45.00 mmYes

Scaling

Deleted observations

Zero sigma or profile test7689
Overload or incomplete profile  80
Sigma cutoff  36

Final Data Set

Scale factor1.00
Number of 'full' reflections  4661
Number of 'partial' reflections 16385
Total number of integrated reflections  5854
Total number of unique reflections  4215
Data completeness  38.1%
Resolution range99.00-0.70 A
Theta range0.21°-30.51°
Average Intensity   22.2
Average Sigma(I)   10.2
Overall R-merge (linear)  0.156

Crystal Information

Collection Temperature   150 K
Crystal Size    x   x  
Crystal Colour  
Crystal Shape  

SORTAV Absorption correction Summary

R(merge) on F2
Before
After
R
0.072
0.089
Rw
0.130
0.145
Max Transmission Factor
0.522E+00
Min Transmission Factor
0.522E+00

N.B. The scaling summary is redundant as outliers are treated during the absorption correction using SORTAV.
The quoted data completeness is for the stated resolution ranges, and the Overall R-merge is that before the absorption correction.
The SORTAV transmission factors are based on a crude approximation and the expected formula (not always correct).
For more information visit the service web site at: http://www.soton.ac.uk/~xservice/