EPSRC National Crystallography Service
Data Collection Summary
Summary report for Directory: diska/02src193
Report generated Apr 16, 2002; 19:49:44
Unit cell
63799 reflections with 2.91°<theta<27.48° (resolution between
7.00A and 0.77A) were used for unit cell refinement
Symmetry used
in scalepack |
p1 |
a (Angstrom) |
11.9924 +/- 0.0017 |
b (Angstrom) |
17.129 +/- 0.002 |
c (Angstrom) |
18.103 +/- 0.003 |
alpha (°) |
103.816 +/- 0.005 |
beta (°) |
90.240 +/- 0.006 |
gamma (°) |
110.361 +/- 0.012 |
Volume (A**3) |
3369.8 +/- 0.9 |
Mosaicity (°) |
3.361 +/- 0.009 |
Data collection
Summary
Total number of images collected |
228 |
Total exposure time |
75.5 minutes |
Data collection exposure time |
74.1 minutes |
Data collection wall-clock time |
104.6 minutes |
Experimental Conditions
Wavelength |
0.71073 A |
Generator setting |
50kV 85mA |
Crystal to detector distance |
30.00 mm |
Scans
Type |
Name |
# images |
Total
Rotation |
Per frame
Rotation |
Exposure
per frame |
Used in
scaling |
data collection |
s01f |
181 |
362.0° phi |
2.000° |
20 seconds |
Yes |
data collection |
s02f |
16 |
32.0° omega |
2.000° |
20 seconds |
Yes |
data collection |
s03f |
23 |
46.0° omega |
2.000° |
20 seconds |
Yes |
Phi/Chi |
i01f - i08f |
8 |
|
|
10 seconds |
Scalepack Scaling
Deleted observations
Zero sigma or profile test |
195 |
Overload or incomplete profile |
2570 |
Sigma cutoff |
979 |
High resolution limit |
458 |
Final Data Set
Scale factor |
10.00 |
Number of 'full' reflections |
677 |
Number of 'partial' reflections |
134749 |
Total number of integrated reflections |
16003 |
Total number of unique reflections |
8243 |
Data completeness |
52.8% |
Resolution range |
7.00-0.77 A |
Theta range |
2.91°-27.48° |
Average Intensity |
14.6 |
Average Sigma(I) |
3.1 |
Overall R-merge (linear) |
0.101 |
Crystal Information
Collection Temperature |
120 K |
Crystal Size |
0.15 x 0.10 x 0.08 |
Crystal Colour |
Colourless |
Crystal Shape |
Block |
SORTAV Absorption correction
Max Transmission Factor |
0.97819
|
Min Transmission Factor |
0.95642
|
N.B. The scaling summary is redundant as outliers are treated during
the absorption correction using SORTAV. The quoted data completeness is
for the stated resolution ranges, and the Overall R-merge is that before
the absorption correction. The SORTAV transmission factors are based on
a crude approximation and the expected formula (not always correct!). For
more information visit the service web site at: http://www.soton.ac.uk/~xservice/