EPSRC National Crystallography Service
Data Collection Summary
Summary report for Directory: diska/02sot051
Report generated May 03, 2002; 17:26:01
Unit cell
18333 reflections with 2.91°<theta<27.48° (resolution between
7.00A and 0.77A) were used for unit cell refinement
 
 
Symmetry used
 in scalepack | 
p1 | 
| a (Angstrom) | 
8.9559 +/- 0.0004 | 
| b (Angstrom) | 
9.0489 +/- 0.0004 | 
| c (Angstrom) | 
24.0779 +/- 0.0013 | 
| alpha (°) | 
85.0155 +/- 0.0015 | 
| beta (°) | 
88.2630 +/- 0.0014 | 
| gamma (°) | 
87.5380 +/- 0.0018 | 
| Volume (A**3) | 
1941.43 +/- 0.16 | 
| Mosaicity (°) | 
1.118 +/- 0.003 | 
Data collection
Summary
| Total number of images collected | 
194 | 
| Total exposure time | 
63.8 minutes | 
| Data collection exposure time | 
62.7 minutes | 
| Data collection wall-clock time | 
88.3 minutes | 
Experimental Conditions
| Wavelength | 
0.71073 A | 
| Generator setting | 
50kV 85mA | 
| Crystal to detector distance | 
40.00 mm | 
Scans
| Type | 
Name | 
# images | 
Total
 Rotation | 
Per frame
 Rotation | 
Exposure
 per frame | 
Used in
 scaling | 
| data collection | 
s01f | 
181 | 
362.0° phi | 
2.000° | 
20 seconds | 
Yes | 
| data collection | 
s02f | 
5 | 
 10.0° omega | 
2.000° | 
20 seconds | 
No | 
| Phi/Chi | 
i01f - i08f | 
8 | 
 | 
 | 
8 seconds | 
Scalepack Scaling
Deleted observations
| Overload or incomplete profile | 
 418 | 
| Sigma cutoff | 
  37 | 
| High resolution limit | 
  51 | 
Final Data Set
| Scale factor | 
10.00 | 
| Number of 'full' reflections | 
  1668 | 
| Number of 'partial' reflections | 
 26968 | 
| Total number of integrated reflections | 
 13849 | 
| Total number of unique reflections | 
  6538 | 
| Data completeness | 
  73.8% | 
| Resolution range | 
7.00-0.77 A | 
| Theta range | 
2.91°-27.48° | 
| Average Intensity | 
   77.2 | 
| Average Sigma(I) | 
    3.7 | 
| Overall R-merge (linear) | 
  0.051 | 
Crystal Information
| Collection Temperature | 
  120 K | 
| Crystal Size | 
 0.3 x 0.14 x 0.1 | 
| Crystal Colour | 
 colourless | 
| Crystal Shape | 
 prism | 
 
 
SORTAV Absorption correction
| Max Transmission Factor | 
0.97494 
 | 
| Min Transmission Factor | 
0.93631 
 | 
N.B. The scaling summary is redundant as outliers are treated during
the absorption correction using SORTAV. The quoted data completeness is
for the stated resolution ranges, and the Overall R-merge is that before
the absorption correction. The SORTAV transmission factors are based on
a crude approximation and the expected formula (not always correct!). For
more information visit the service web site at: http://www.soton.ac.uk/~xservice/