checkCIF/PLATON report (basic structural check)

No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: s92
Bond precision: C-C = 0.0030 A Wavelength=0.71073
Cell: a=14.261(3) b=11.346(2) c=17.586(4)
alpha=90 beta=109.22(3) gamma=90
Temperature: 150 K
Calculated Reported
Volume 2686.9(11) 2686.8(9)
Space group P 21/c P2(1)/c
Hall group -P 2ybc ?
Moiety formula C16 H32 Cl2 N3 O10 P3 ?
Sum formula C16 H32 Cl2 N3 O10 P3 C16 H32 Cl2 N3 NA0 O10 P3
Mr 590.26 590.26
Dx,g cm-3 1.459 1.459
Z 4 4
Mu (mm-1) 0.472 0.472
F000 1232.0 1232.0
F000' 1234.98
h,k,lmax 18,14,22 18,14,22
Nref 6166 6125
Tmin,Tmax 0.868,0.889 0.834,0.891
Tmin' 0.828
Correction method= MULTI-SCANS
Data completeness= 0.993 Theta(max)= 27.470
R(reflections)= 0.0362( 4867) wR2(reflections)= 0.0964( 6125)
S = 1.031 Npar= 308

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level A PLAT031_ALERT_4_A Refined Extinction Parameter within Range ...... 0.00 Sigma PLAT093_ALERT_1_A No su's on H-atoms, but refinement reported as . mixed
Alert level C ABSTY02_ALERT_1_C An _exptl_absorpt_correction_type has been given without a literature citation. This should be contained in the _exptl_absorpt_process_details field. Absorption correction given as multi-scans SHFSU01_ALERT_2_C The absolute value of parameter shift to su ratio > 0.05 Absolute value of the parameter shift to su ratio given 0.093 Additional refinement cycles may be required. PLAT080_ALERT_2_C Maximum Shift/Error ............................ 0.09 PLAT041_ALERT_1_C Calc. and Reported SumFormula Strings Differ ? PLAT152_ALERT_1_C Supplied and Calc Volume s.u. Inconsistent ..... ?
Alert level G ABSTY01_ALERT_1_G Extra text has been found in the _exptl_absorpt_correction_type field, which should be only a single keyword. A literature citation should be included in the _exptl_absorpt_process_details field. CELLZ01_ALERT_1_G Difference between formula and atom_site contents detected. CELLZ01_ALERT_1_G ALERT: Large difference may be due to a symmetry error - see SYMMG tests From the CIF: _cell_formula_units_Z 4 From the CIF: _chemical_formula_sum C16 H32 Cl2 N3 Na0 O10 P3 TEST: Compare cell contents of formula and atom_site data atom Z*formula cif sites diff C 64.00 64.00 0.00 H 128.00 128.00 0.00 Cl 8.00 8.00 0.00 N 12.00 12.00 0.00 Na 4.00 0.00 4.00 O 40.00 40.00 0.00 P 12.00 12.00 0.00
2 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 5 ALERT level C = Check and explain 3 ALERT level G = General alerts; check 7 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 2 ALERT type 2 Indicator that the structure model may be wrong or deficient 0 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Publication of your CIF in IUCr journals

A basic structural check has been run on your CIF. These basic checks will be run on all CIFs submitted for publication in IUCr journals (Acta Crystallographica, Journal of Applied Crystallography, Journal of Synchrotron Radiation); however, if you intend to submit to Acta Crystallographica Section C or E, you should make sure that full publication checks are run on the final version of your CIF prior to submission.

Publication of your CIF in other journals

Please refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission.


PLATON version of 19/05/2009; check.def file version of 13/05/2009
Datablock s92 - ellipsoid plot

Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry