EPSRC National Crystallography Service
Data Collection Summary
Summary report for Directory: diska/00src404
Report generated Sep 20, 2000; 07:47:38
Unit cell
10967 reflections with 2.91°<theta<43.11° (resolution between
7.00A and 0.52A) were used for unit cell refinement
 
 
| Symmetry used in scalepack
 | p2 | 
| a (Angstrom) | 10.8189 +/- 0.0002 | 
| b (Angstrom) | 10.8238 +/- 0.0002 | 
| c (Angstrom) | 16.4884 +/- 0.0003 | 
| alpha (°) | 90.000 | 
| beta (°) | 108.8958 +/- 0.0008 | 
| gamma (°) | 90.000 | 
| Volume (A**3) | 1826.76 +/- 0.06 | 
| Mosaicity (°) | 0.338 +/- 0.002 | 
Data collection
Summary
| Total number of images collected | 193 | 
| Total exposure time | 63.7 minutes | 
| Data collection exposure time | 62.3 minutes | 
| Data collection wall-clock time | 84.1 minutes | 
Experimental Conditions
| Wavelength | 0.71073 A | 
| Generator setting | 50.00kV 80.00mA | 
| Crystal to detector distance | 30.00 mm | 
Scans
| Type | Name | # images | Total Rotation
 | Per frame Rotation
 | Exposure per frame
 | Used in scaling
 | 
| data collection | s01f | 95 | 95.0° omega | 1.000° | 20 seconds | Yes | 
| data collection | s02f | 90 | 90.0° omega | 1.000° | 20 seconds | Yes | 
Final Data Set
| Scale factor | 10.00 | 
| Number of 'full' reflections | 6712 | 
| Number of 'partial' reflections | 14155 | 
| Total number of integrated reflections | 12963 | 
| Total number of unique reflections | 4963 | 
| Data completeness | 35.2% | 
| Resolution range | 7.00-0.52 A | 
| Theta range | 2.91°-43.11° | 
| Average Intensity | 58.3 | 
| Average Sigma(I) | 3.6 | 
| Overall R-merge (linear) | 0.060 | 
Crystal Information
| Collection Temperature | 150 K | 
| Crystal Size | 0.2 x 0.2 x 0.1 | 
| Crystal Colour | Colourless | 
| Crystal Shape | Block 
 | 
SORTAV Absorption correction Summary
| R(merge) on F2 | Before | After | 
| R | 0.075 | 0.061 | 
| Rw | 0.092 | 0.082 | 
| Max Transmission Factor | 0.937E+00 | 
| Min Transmission Factor | 0.828E+00 | 
N.B. The scaling summary is redundant as outliers are treated during
the absorption correction using SORTAV.
The quoted data completeness is for the stated resolution ranges, and
the Overall R-merge is that before the absorption correction.The SORTAV
transmission factors are based on a crude approximation and the expected
formula (not always correct).For more information visit the service web
site at: http://www.soton.ac.uk/~xservice/