No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: 2008lsh022
Bond precision: C-C = 0.0042 A Wavelength=0.71073
Cell: a=9.2339(3) b=11.9540(4) c=13.4630(4)
alpha=64.502(2) beta=87.652(2) gamma=76.670(2)
Temperature: 120 K
Calculated Reported
Volume 1302.32(8) 1302.32(7)
Space group P -1 P-1
Hall group -P 1 ?
Moiety formula C15 H16 N2 O3 ?
Sum formula C15 H16 N2 O3 C15 H16 N2 O3
Mr 272.30 272.30
Dx,g cm-3 1.389 1.389
Z 4 4
Mu (mm-1) 0.098 0.098
F000 576.0 576.0
F000' 576.27
h,k,lmax 11,15,17 11,15,17
Nref 5982 5928
Tmin,Tmax 0.998,0.999 0.971,0.999
Tmin' 0.971
Correction method= MULTI-SCAN
Data completeness= 0.991 Theta(max)= 27.500
R(reflections)= 0.0731( 4217) wR2(reflections)= 0.1485( 5928)
S = 1.103 Npar= 381

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level B PLAT112_ALERT_2_B ADDSYM Detects Additional (Pseudo) Symm. Elem... X
Author Response: see comments under _refine_special_details

Alert level C PLAT152_ALERT_1_C Supplied and Calc Volume s.u. Inconsistent ..... ?
Alert level G PLAT860_ALERT_3_G Note: Number of Least-Squares Restraints ....... 4 PLAT066_ALERT_1_G Predicted and Reported Transmissions Identical . ? PLAT154_ALERT_1_G The su's on the Cell Angles are Equal (x 10000) 200 Deg. PLAT180_ALERT_4_G Check Cell Rounding: # of Values Ending with 0 = 3
0 ALERT level A = In general: serious problem 1 ALERT level B = Potentially serious problem 1 ALERT level C = Check and explain 4 ALERT level G = General alerts; check 3 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 1 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check


Publication of your CIF in IUCr journals

A basic structural check has been run on your CIF. These basic checks will be run on all CIFs submitted for publication in IUCr journals (Acta Crystallographica, Journal of Applied Crystallography, Journal of Synchrotron Radiation); however, if you intend to submit to Acta Crystallographica Section C or E, you should make sure that full publication checks are run on the final version of your CIF prior to submission.

Publication of your CIF in other journals

Please refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission.


PLATON version of 25/02/2009; check.def file version of 25/02/2009
Datablock 2008lsh022 - ellipsoid plot

Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry