EPSRC National Crystallography Service
Data Collection Summary
Summary report for Directory: diska/02sot077
Report generated Jul 02, 2002; 14:30:57
Unit cell
41356 reflections with 2.91°<theta<27.48° (resolution between
7.00A and 0.77A) were used for unit cell refinement
Symmetry used
in scalepack |
p1 |
a (Angstrom) |
11.0968 +/- 0.0004 |
b (Angstrom) |
11.1517 +/- 0.0004 |
c (Angstrom) |
11.9917 +/- 0.0005 |
alpha (°) |
102.2326 +/- 0.0015 |
beta (°) |
95.6879 +/- 0.0016 |
gamma (°) |
92.374 +/- 0.003 |
Volume (A**3) |
1440.14 +/- 0.10 |
Mosaicity (°) |
1.572 +/- 0.003 |
Data collection
Summary
Total number of images collected |
229 |
Total exposure time |
134.7 minutes |
Data collection exposure time |
133.4 minutes |
Data collection wall-clock time |
166.9 minutes |
Experimental Conditions
Wavelength |
0.71073 A |
Generator setting |
50kV 80mA |
Crystal to detector distance |
30.00 mm |
Scans
Type |
Name |
# images |
Total
Rotation |
Per frame
Rotation |
Exposure
per frame |
Used in
scaling |
data collection |
s01f |
181 |
362.0° phi |
2.000° |
36 seconds |
Yes |
data collection |
s02f |
17 |
34.0° omega |
2.000° |
36 seconds |
Yes |
data collection |
s03f |
23 |
46.0° omega |
2.000° |
36 seconds |
Yes |
Phi/Chi |
i01f - i08f |
8 |
|
|
10 seconds |
Scalepack Scaling
Deleted observations
Zero sigma or profile test |
1 |
Overload or incomplete profile |
798 |
Sigma cutoff |
254 |
High resolution limit |
27 |
Final Data Set
Scale factor |
10.00 |
Number of 'full' reflections |
743 |
Number of 'partial' reflections |
52458 |
Total number of integrated reflections |
21444 |
Total number of unique reflections |
6440 |
Data completeness |
97.7% |
Resolution range |
7.00-0.77 A |
Theta range |
2.91°-27.48° |
Average Intensity |
76.9 |
Average Sigma(I) |
3.5 |
Overall R-merge (linear) |
0.051 |
Crystal Information
Collection Temperature |
120 K |
Crystal Size |
0.16 x 0.12 x 0.06 |
Crystal Colour |
orange |
Crystal Shape |
block |
SORTAV Absorption correction
Max Transmission Factor |
0.98411
|
Min Transmission Factor |
0.93072
|
N.B. The scaling summary is redundant as outliers are treated during
the absorption correction using SORTAV. The quoted data completeness is
for the stated resolution ranges, and the Overall R-merge is that before
the absorption correction. The SORTAV transmission factors are based on
a crude approximation and the expected formula (not always correct!). For
more information visit the service web site at: http://www.soton.ac.uk/~xservice/