checkCIF/PLATON report (basic structural check)
No syntax errors found. CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: 2008lsh161
Bond precision: |
|
Wavelength= |
Cell: |
a= |
b= |
c= |
|
alpha= |
beta= |
gamma= |
Temperature: |
? |
|
|
|
Calculated |
Reported |
Volume |
|
|
Space group |
|
|
Hall group |
|
|
Moiety formula |
|
|
Sum formula |
|
|
Mr |
|
|
Dx,g cm-3 |
|
|
Z |
|
|
Mu (mm-1) |
|
|
F000 |
|
|
F000' |
|
|
h,k,lmax |
|
|
Nref |
|
|
Tmin,Tmax |
|
|
Tmin' |
|
|
Correction method= Not given |
|
Data completeness= |
Theta(max)= |
R(reflections)= |
wR2(reflections)= |
The following ALERTS were generated. Each ALERT has the format
test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.
Alert level C
STRVA01_ALERT_2_C Chirality of atom sites is inverted?
From the CIF: _refine_ls_abs_structure_Flack 2.300
From the CIF: _refine_ls_abs_structure_Flack_su 1.700
Alert level G
REFLT03_ALERT_4_G ALERT: MoKa measured Friedel data cannot be used to
determine absolute structure in a light-atom
study EXCEPT under VERY special conditions.
It is preferred that Friedel data is merged in such cases.
From the CIF: _diffrn_reflns_theta_max 27.48
From the CIF: _reflns_number_total 2019
Count of symmetry unique reflns 1066
Completeness (_total/calc) 189.40%
TEST3: Check Friedels for noncentro structure
Estimate of Friedel pairs measured 953
Fraction of Friedel pairs measured 0.894
Are heavy atom types Z>Si present no
0 ALERT level A = In general: serious problem
0 ALERT level B = Potentially serious problem
1 ALERT level C = Check and explain
1 ALERT level G = General alerts; check
0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data
1 ALERT type 2 Indicator that the structure model may be wrong or deficient
0 ALERT type 3 Indicator that the structure quality may be low
1 ALERT type 4 Improvement, methodology, query or suggestion
0 ALERT type 5 Informative message, check
Publication of your CIF in IUCr journals
A basic structural check has been run on your CIF.
These basic checks will be run on all CIFs submitted for publication in
IUCr journals (Acta Crystallographica, Journal of Applied Crystallography,
Journal of Synchrotron Radiation); however, if you intend to submit to Acta
Crystallographica Section C or E, you should make sure that
full publication
checks are run on the final version of your CIF prior to submission.
Publication of your CIF in other journals
Please refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission.
|
PLATON version of ; check.def file version of
Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry