No syntax errors found. CIF dictionaryDatablock: s92
Please wait while processing .... Interpreting this report
Bond precision: | C-C = 0.0030 A | Wavelength=0.71073 |
Cell: | a=9.6325(3) | b=16.6358(6) | c=9.8585(3) |
alpha=90 | beta=103.591(2) | gamma=90 | |
Temperature: | 120 K |
Calculated | Reported | |
Volume | 1535.53(9) | 1535.53(9) |
Space group | P 21/n | P21/n |
Hall group | -P 2yn | -P 2yn |
Moiety formula | C13 H19 N2, F6 P | C13 H19 N2, F6 P |
Sum formula | C13 H19 F6 N2 P | C13 H19 F6 N2 P |
Mr | 348.27 | 348.27 |
Dx,g cm-3 | 1.507 | 1.506 |
Z | 4 | 4 |
Mu (mm-1) | 0.240 | 0.240 |
F000 | 720.0 | 720.0 |
F000' | 720.93 | |
h,k,lmax | 11,19,11 | 11,19,11 |
Nref | 2712 | 2703 |
Tmin,Tmax | 0.958,0.976 | 0.954,0.976 |
Tmin' | 0.953 |
Correction method= MULTI-SCAN |
Data completeness= 0.997 | Theta(max)= 25.020 |
R(reflections)= 0.0377( 2336) | wR2(reflections)= 0.1013( 2703) |
S = 1.032 | Npar= 202 |
The following ALERTS were generated. Each ALERT has the format test-name_ALERT_alert-type_alert-level. Click on the hyperlinks for more details of the test.Alert level C PLAT432_ALERT_2_C Short Inter X...Y Contact F6 .. C4 .. 2.89 Ang.
Alert level G PLAT128_ALERT_4_G Non-standard setting of Space-group P21/c .... P21/n
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 1 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 1 ALERT type 2 Indicator that the structure model may be wrong or deficient 0 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check
Publication of your CIF in IUCr journals
A basic structural check has been run on your CIF. These basic checks will be run on all CIFs submitted for publication in IUCr journals (Acta Crystallographica, Journal of Applied Crystallography, Journal of Synchrotron Radiation); however, if you intend to submit to Acta Crystallographica Section C or E, you should make sure that full publication checks are run on the final version of your CIF prior to submission. Publication of your CIF in other journalsPlease refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission. |
Datablock s92 - ellipsoid plot |
![]() |