Unit cell

2152 reflections with 2.91°<theta<27.48° (resolution between 7.00A and 0.77A) were used for unit cell refinement

Symmetry used
in scalepack
p1
a (Angstrom)7.2995 +/- 0.0004
b (Angstrom)7.2873 +/- 0.0004
c (Angstrom)17.1050 +/- 0.0014
alpha (°) 89.908
beta (°) 89.976
gamma (°) 120.117
Volume (A**3)787.05 +/- 0.09
Mosaicity (°)0.535 +/- 0.007

Data collection

Summary

Total number of images collected140
Total exposure time144.0 minutes
Data collection exposure time141.3 minutes
Data collection wall-clock time152.6 minutes

Experimental Conditions

Wavelength0.71073 A
Crystal to detector distance30.00 mm

Scans

TypeName# imagesTotal
Rotation
Per frame
Rotation
Exposure
per frame
Used in
scaling
data collections01f83166.0° phi2.000°64 secondsYes
data collections02f49 98.0° omega2.000°64 secondsYes
Phi/Chii01f - i08f820 seconds

Scalepack Scaling

Deleted observations

Rejected  25
Zero sigma or profile test   5
Overload or incomplete profile 180
Sigma cutoff   7
High resolution limit  20

Final Data Set

Scale factor range9.74-10.06
Number of 'full' reflections  4840
Number of 'partial' reflections  2911
Total number of integrated reflections  6701
Total number of unique reflections  3302
Data completeness  90.9%
Resolution range7.00-0.77 A
Theta range2.91°-27.48°
Average Intensity   24.3
Average Sigma(I)    1.9
Overall R-merge (linear)  0.044

Sadabs Results

Parameter refinement on 1742 reflections reduced R(int) from 0.0424 to 0.0273

Before rejection, 7469 reflections total and 3439 unique

After rejection, 7403 reflections total and 3433 unique

Runs

  Run 2-theta  R(int)  Incid. factors  Diffr. factors    K     Total I>2sig(I)
    1    7.4  0.0409   0.949 - 1.025   0.907 - 1.118   1.255    4668    1361
    2    7.2  0.0476   0.901 - 0.984   0.932 - 1.100   1.204    2735     803
Ratio of minimum to maximum apparent transmission: 0.811290

Metadata

  Group    Service  
  Operator   Simon Coles  
  Sample Owner   Wills  
  Local Code   KFe  
  Formula     
  Crystal Colour    Orange  
  Crystal Habit    Block  
  Crystal Size   0.08 x 0.08 x 0.08 (mm3) 
  Temperature   120(K) 
  Generator   50 (kV)   85 (mA) 
  Primary Solvent     
  Other Solvents     

File Explanations

SampleCode.zip
      SampleCode.hkl - data corrected using  SADABS
      SampleCode_merge_none.hkl - equivalents and friedels kept separate  (See "Final Data Set" table in this report)
      SampleCode.p4p - skeleton p4p file for use with XPREP
      SampleCode.htm - this summary file


Southampton CIF entry fields

_exptl_absorpt_process_details       'SADABS V2.10 (Sheldrick, G.M., 2003)'

_diffrn_ambient_temperature           120(2)
_diffrn_radiation_wavelength           0.71073
_diffrn_radiation_type                      MoK\a
_diffrn_radiation_source                  'Bruker-Nonius FR591 rotating anode'
_diffrn_radiation_monochromator    'graphite'
_diffrn_measurement_device_type  'Bruker-Nonius 95mm CCD camera on \k-goniostat'
_diffrn_measurement_method          '\f & \w scans'
_diffrn_detector_area_resol_mean   9.091

_computing_data_collection        
'COLLECT (Hooft, R.W.W., 1998)'
_computing_cell_refinement        
'DENZO (Otwinowski & Minor, 1997) & COLLECT (Hooft, R.W.W., 1998)'
#Although determined using DirAx, the cell is refined in the HKL
#package during data reduction
_computing_data_reduction         
'DENZO (Otwinowski & Minor, 1997) & COLLECT (Hooft, R.W.W., 1998)' 

Software References

Unit Cell Determination using DirAx:
Duisenberg AJM. Indexing in Single-Crystal Diffractometry with an Obstinate List of Reflections. Journal of Applied Crystallography 1992; 25: 92-96.
Duisenberg AJM, Hooft RWW, Schreurs AMM, Kroon J. Accurate cells from area-detector images. Journal of Applied Crystallography 2000; 33: 893-898.

Diffractometer control and strategy calculation using COLLECT:
Hooft RWW. COLLECT data collection software, Nonius B.V., 1998.

Standard Data Reduction using HKL(Denzo & Scalepack):
Otwinowski Z, Minor W. Processing of X-ray diffraction data collected in oscillation mode. Macromolecular Crystallography, Pt A. 1997; 276: 307-326.

Absorption Correction
Sheldrick, G. M. (2003). SADABS. Version 2.10. Bruker AXS Inc., Madison, Wisconsin, USA.

Non-Standard Data Reduction using EvalCCD:
Duisenberg AJM, Kroon-Batenburg LMJ, Schreurs AMM. An intensity evaluation method: EVAL-14. Journal of Applied Crystallography 2003; 36: 220-229.

For more information visit the service web site at: http://www.soton.ac.uk/~xservice/